Projects

  • 11/2015 - 09/2016
    Seed transportation and cleaning lines for Bunge port terminal Mykolaiv
    SCADA WinCC 7.2, PLC Siemens SIMATIC S7-416 (Step 7 V5.5), ET200M distributed I/O stations, Sinamics G120P (Sinamics Starter) frequency converters, Simocode Pro V (Simocode ES) control and protection devices

    Customer: SP APS LLC. Automation system for the sunflower seed transportation and cleaning lines as part of production and processing complex, as well as its integration with the other sites. Automated equipment: 3 silos with discrete and radar (analogue) level sensors, 4 silo dust aspiration fans, 7 bucket elevators, 33 conveyors, 10 dust aspiration filters, […]

    Read more

  • 08/2016 - 09/2016
    Automation system for dryer Mega, Bunge Mykolaiv
    SCADA WinCC 7.2; PLC Siemens SIMATIC S7-1200 (TIA Portal V13 SP1)

    Customer: SP APS LLC. Automation system for a three-tower dryer Mega, as part of production and processing complex, including its integration into the overall system. Automated equipment: 15 fans and common dust aspiration (rotary-valve feeder and fan), 3 discharge mechanisms with controlled speed of discharge, 9 discrete level sensors and 12 temperature transmitters (3 for […]

    Read more

  • 07/2015 - 12/2015
    Automation system for storage and processing terminal of sunflower seeds, Bunge Nikolaev
    SCADA WinCC 7.2, PLC Siemens SIMATIC S7-416 (Step 7 V5.5), remote IO stations ET200M and ET200iSP, frequency converters Sinamics G120P (SINAMICS Starter), control and protection devices Simocode Pro V (Simocode ES)

    Customer: SP APS LLC. Automation system for the​​ storage and processing terminal of sunflower seeds as a part of production and processing complex. Automated equipment: 11 silos with discrete and radar (analogue) level sensors, screws with hydro stations, mobile units for silo dust aspiration, 4 bucket elevators, 25 transporters, 6 dust aspiration filters, 10 electric […]

    Read more

  • 01/2015 - 04/2015
    Automation system for storage and transshipment terminal of vegetable oil, Bunge Mykolaiv
    Siemens SIMATIC PLC S7-416, HMI KTP400, industrial computers; Step 7, WinCC 7.2, WinCC Flexible 2008

    Customer: SP APS LLC. Automation system for vegetable oil storage and transshipment terminal: 6 tanks (level transmitters and level switches at top-level, 18 temperature sensors in each tank), 7 pumps with variable speed drive Sinamics, 15 mixers with soft starter Simocode, 63 electrically driven valves, 2 compressors, automated route management.

    Read more

  • 03/2014 - 05/2014
    Installation of frequency inverter on Unisab compressor, Slavutich Zaporozhye
    Siemens SIMATIC PLC Siemens S7-317, Step7, WinCC Flexible, WinCC, frequency converter Danfoss VLT HVAC Drive FC102, 560 kW, Profibus DP V1

    Customer: Carlberg “Slavutich” brewery Installing an inverter on a screw compressor unit SAB 283S with the control system Uisab, within ammonia refrigeration installation, to provide optimal regulation of the compressor capacity (slide, frequency) in terms of energy consumption and wear of mechanisms as well as for optimal collaboration of several compressors of different capacity.

    Read more

  • 06/2013 - 09/2013
    Extension of refrigeration automation system for Rogan brewery, SUN InBev Kharkiv
    SIMATIC Step7, WinCC Flexible 2008, SCADA iFix 5.5. CPU S7 414-2 DP, S7 315-2 DP.

    Customer: NPP Holod LLC. Upgrade of automation system of refrigeration plant. New equipment added: liquid separator, plate heat exchangers (2 pcs.), buffer tank and pumps (2 pcs.) of warm circuit, buffer tank and pumps (3 pcs.) of cold circuit; freecooling system: dry cooling tower fans (18 pcs.), ethanol pump, plate heat exchanger. Integration into energy-consumption […]

    Read more

  • 11/2012 - 06/2013
    Refrigeration system automation system for Slavutych brewery, Zaporizhia
    SIMATIC Step7 v5.5, WinCC Flexible 2008, PCschematic Automation, WinCC v6.2, PCS7. PLC S7 317-2DP, operator panel TP277

    Customer: Slavutich Brewery, Zaporozhye. Development of electrical project documentation and software for automation system of refrigeration installation: piston compressor units – 4 pcs, screw compressors – 4 pcs; evaporative condensers – 2 pcs, water purification system; ammonia pumps – 2 pcs; glycol pumps – 4 pcs; water pumps with frequency control – 6 pcs; liquid […]

    Read more

  • 01/2012 - 09/2012
    Extension of refrigeration SCADA system for Danone-Dnipro
    SIMATIC Step7, WinCC SCADA v6.2. CPU S7-414.

    Customer: Johnson Controls Inc. (York) – Danone-Dnipro Milk Factory – Danone. Ukraine, Kherson. Upgrade of SCADA system for refrigeration installation: added heat pumps Sabroe Heatpac 108S COM001, glycol heat exchangers Thermowave TL0650KDK-1500 – HXP003, 2 glycol pumps Grundfoss TP 150-280/4, two motor valves Danfoss ICM150.

    Read more

  • 09/2010 - 10/2011
    Energy consumption optimization in refrigeration plant for Danone, Kherson
    SIMATIC Step7, WinCC SCADA v6.2. CPU S7-414, industrial computer. Socomec DIRIS A40 electrical meter.

    Customer: Johnson Controls Inc. (York) – Danone-Dnipro Milk Factory – Danone. Ukraine, Kherson. Upgrade of SCADA for refrigeration plant with the purpose of energy consumption optimization. Connect Socomec DIRIS A40 meter via Profibus DP to CPU S7-414 for monitoring of electrical parameters. Install CP Optimizer Sabroe R717 to calculate the optimal discharge pressure setpoint. Alternative […]

    Read more

  • 09/2010 - 10/2011
    Extension of refrigeration SCADA for energy optimization for Danone, Kherson
    SIMATIC Step7, WinCC SCADA v6.2. CPU S7-414, industrial computer. Socomec DIRIS A40 electrical meter.

    Customer: Johnson Controls Inc. (York) – Danone-Dnipro Milk Factory – Danone. Ukraine, Kherson. Upgrade of SCADA for refrigeration plant with the purpose of energy consumption optimization. Connect Socomec DIRIS A40 meter via Profibus DP to CPU S7-414 for monitoring of electrical parameters. Install CP Optimizer Sabroe R717 to calculate the optimal discharge pressure setpoint. Alternative […]

    Read more

  • 02/2011 - 04/2011
    Extension of refrigeration SCADA system for SABMiller Kaluga Brewing Company, Russia
    SIMATIC Step7, WinCC SCADA v7.0. CPU S7 414-2 DP, S7 315-2 DP

    Customer: SABMiller – Kaluga Brewing Company. Russia, Kaluga. Upgrade of SCADA system for refrigeration plant. Modification of compressor sequence algorithm to provide the optimal load with the consideration of compressors’ power. Efficiency monitoring of ammonia refrigerating system according to data from flow meters, temperature transmitters and electrical meters.

    Read more

  • 08/2010 - 02/2011
    Extension of SCADA for refrigeration plant for Cheese Club, Kaniv
    SIMATIC Step7, WinCC6. CPU S7-314 with Ethernet, PC.

    Customer: Khaldotechnika – Kaniv butter-cheese factory – “Cheese Club” Corporation. Ukraine, Kaniv. Upgrade of SCADA for refrigeration plant, added: 2 freon chillers CIAT LWN2800, 2 air condensers, 4 glycol and water pumps, 2 heat-exchangers. Communication with the chillers over RS485 Modbus network.

    Read more

  • 08/2010 - 09/2010
    Extension of refrigeration SCADA for Cheese Club, Kaniv
    SIMATIC Step7, WinCC6. CPU S7-314 with Ethernet, PC.

    Customer: Khaldotechnika – Kaniv butter-cheese factory – “Cheese Club” Corporation. Ukraine, Kaniv. Upgrade of SCADA for refrigeration plant, added: 2 freon chillers CIAT LWN2800, 2 air condensers, 4 glycol and water pumps, 2 heat-exchangers. Communication with the chillers over RS485 Modbus network.

    Read more

  • 06/2009 - 07/2009
    Extension of the refrigeration automation system for Slavutich brewery
    SIMATIC Step7, WinCC Flexible 2008. CPU S7-315, MP277.

    Customer: York – BBH “Slavutich” Brewery, Ukraine, Zaporizhia Upgrade of the refrigeration automation system: discharge pressure optimizer installed for energy saving.

    Read more

  • 07/2008 - 02/2009
    Extension of refrigeration automation system for Desna brewery
    SIMATIC Step7, WinCC Flexible 2007. CPU S7-315, MP270B.

    Customer: Johnson Controls Inc. (York) – Desna Brewery (InBev). Ukraine, Chernigov. Added equipment: 2 screw compressor units, 1 ice water pump, 1 heat exchanger.

    Read more

  • 09/2007 - 05/2008
    Automation of refrigeration system for Danone Kherson
    SIMATIC Step7, WinCC SCADA v6.2. CPU S7-414

    Customer: Johnson Controls Inc. (York) – Danone-Dnipro Dairy – Danone. Ukraine, Kherson. Automation of refrigeration system: 2 screw compressor units, 1 double evaporative condenser, 1 liquid separator, 2 ammonia pumps, BUCO ice generator: 1 water pump with frequency converter, 4 water pumps, air compressor, 3 heat-exchanging sections (suction, liquid supply and hot gas valves). Supply […]

    Read more

  • 04/2007 - 04/2008
    Automation of refrigeration system for Slavutich brewery, Zaporizhia
    SIMATIC Step7, WinCC Flexible 2005. CPU S7-315, MP277.

    Customer: York – “Slavutich” Brewery – BBH. Ukraine, Zaporizhia. Automation of refrigeration system: 4 piston and 4 screw compressor units, 3 single and 2 double evaporative condensers, 2 liquid separators, 1 heat-exchanger, 8 glycol pumps, 2 ammonia pumps.

    Read more

  • 02/2007 - 12/2007
    Extension of refrigeration system for Yantar brewery
    SIMATIC Step7, WinCC Flexible 2005. CPU S7-315, TP270

    Customer: York – InBev Yantar brewery. Ukraine, Nikolaev. Added to phase 2: 2 screw compressor units, 1 double evaporative condenser, 2 PHEs, 1 primary and 1 secondary glycol pumps. Complete software re-design. Startup-and-adjustment commissioning.

    Read more

  • 05/2007 - 11/2007
    HMI/SCADA for refrigeration plant for Cheese Club, Kaniv
    SIMATIC Step7, WinCC6, Delphi. CPU S7-314 with Ethernet, PC.

    Customer: Khaldotechnika – Kaniv butter-cheese factory – “Cheese Club” Corporation. Ukraine, Kaniv. HMI/SCADA for refrigeration plant: 6 freon chillers CIAT LWN2800, 6 air condensers, 11 glycol and water pumps, 4 heat-exchangers. Communication with the chillers over RS485 Modbus network.

    Read more

  • 03/2007 - 09/2007
    Automation of refrigeration system for Kaluga Brewing Company
    SIMATIC Step7, WinCC Flexible 2005, WinCC6. CPU S7-414, CPU S7-416, MP370 (2 pcs), PC, RS2LAN.

    Customer: York – SABMiller – Kaluga Brewing Company. Russia, Kaluga. Automation of refrigeration system. Added new equipment and performed complete refactoring (reprogramming) of the old system. Glycol: 3 Grasso and 1 York screw compressor units, 2 single and 2 double evaporative condensers with 4 external water pumps, 4 PHE chillers, 6 glycol pumps, mixing tank […]

    Read more

  • 02/2006 - 08/2007
    Refrigeration automation system for Gavrylivski poultry, Agromars
    SIMATIC Step7, WinCC Flexible 2005. CPU S7-412-2DP, MP270 Touch.

    Customer: Grasso – Gavrylivski chicken poultry, Agromars. Ukraine, Gavrylivka village. Refrigeration automation system: 4 screw compressor units (2 stages), 2 double evaporative condensers, 5 ammonia pumps, 5 glycol pumps, 10 ammonia plate freezers, 6 ammonia fast freezers, 17 ammonia air-coolers, 24 glycol air-coolers.

    Read more

  • 05/2007 - 07/2007
    Extension of refrigeration system for Rogan brewery
    SIMATIC Step7, ProTool, WinCC Flexible. CPU S7-315 and 414, OP27, MP270B Touch.

    Customer: Grasso – InBev “Rogan” Brewery. Ukraine, Kharkov. Added to phase 4: 2 screw compressor units, 1 double evaporative condenser, 1 heat-exchanger, 4 ethanol pumps.

    Read more

  • 06/2006 - 01/2007
    Extension of refrigeration system for Rogan brewery
    SIMATIC Step7, ProTool, WinCC Flexible. CPU S7-315 and 414, OP27, MP270B Touch.

    Customer: Grasso – InBev Rogan brewery, phase 4. Ukraine, Kharkov. Added to phase 2: 1 liquid separator with motor valve at liquid injection, 1 PHE, 2 ethanol pumps (1 with frequency control). Updated software for the old equipment (including Ethernet communication). Added to phase 3: 1 screw compressor unit, 1 double evaporative condenser.

    Read more

  • 06/2006 - 10/2006
    Extension of refrigeration system for Desna brewery
    SIMATIC Step7, WinCC Flexible. CPU S7-315, MP270B Touch, MP270B.

    Customer: Grasso – InBev Desna brewery. Ukraine, Chernigov. Added to phase 3: 3 evaporative condensers, 1 liquid separator with motor valve at liquid injection, 3 ammonia pumps. Updated software for the old equipment. Added to phase 4: 2 evaporative condensers.

    Read more

  • 02/2006 - 06/2006
    Extension of refrigeration system for Yantar brewery
    SIMATIC Step7, WinCC Flexible 2005. CPU S7-315, TP270.

    Customer: York – Interbrew Yantar brewary, phase 2. Ukraine, Nikolaev. Software engineering, electrical supervision and startup-and-adjustment for refrigeration automation system from phase1 plus: 1 screw compressor unit, 1 double evaporative condenser, 1 Plate Heat Exchanger (PHE), 1 primary and 2 secondary glycol pumps. Electrical supervision and startup for ice-water and air compressor cooling systems.

    Read more

  • 05/2005 - 06/2005
    Refrigeration automation system for Frau Marta Cherkassy
    SIMATIC Step7, WinCC Flexible. CPU S7-315, TP170A

    Customer: GEA Grasso (employed). Cherkassy distribution cold-storage warehouse, Frau Marta. Ukraine, Cherkassy. Refrigeration automation system: 2 double stage screw compressor units, 2 evaporative condensers, 3 ammonia pumps, 1 freezing tunnel.

    Read more

  • 04/2003 - 05/2003
    HMI/SCADA for refrigeration automation system for Kilargo ice-cream factory, Poland
    SIMATIC WinCC. Profibus

    Customer: GEA Grasso (employed). Kilargo ice-cream factory. Poland, Gdynia. HMI/SCADA for refrigeration automation system: 3 screw compressor units, 16 coldstore rooms.

    Read more

  • 01/2003 - 02/2003
    HMI/SCADA for refrigeration automation system for Prosiaczek meat-packing factory, Poland
    SIMATIC WinCC. Profibus

    Customer: GEA Grasso (employed). Prosiaczek meat-packing factory. Poland, Gdynia. HMI/SCADA for refrigeration automation system: 7 screw compressor units, 19 coldstore rooms.

    Read more